Basal – Cylindro-conical dental implant

BASAL – BICORTICALISM AT MAXIMUM POWER

The rounded apex and the spiral with a progressive profile impact and thread into the cortices, making contact without compression for maximum primary stability, anchoring firmly to the laminar bone structures.
  • Basal - Cylindro-conical dental implant

    Request a Call Back

    •  Ask a Question

      Basal - Cylindro-conical dental implant

      Ask a Question


        Share

      BASAL – BICORTICALISM AT MAXIMUM POWER

      The rounded apex and the spiral with a progressive profile impact and thread into the cortices, making contact without compression for maximum primary stability, anchoring firmly to the laminar bone structures.

      IMMEDIATE LOADING AS A GOAL (WITH FULL WARRANTY)

      The anatomical collar, with a rounded and thin apex, and the profile of the truncated cone spiral are the prerequisites for obtaining the ideal contact without compression that makes the basal implants perfect for immediate loading. The final anti-rotational stop and the atraumatic progressive threading complete the fundamental characteristics of these, particularly sharp implants.

      PATENTED, CERTIFIED, AND GUARANTEED DESIGN

      It is the combination of various silhouettes and profiles analyzed and tested over time, which we have improved, to ensure the optimization of the surgery and the success of immediate loading prosthetics. THE

      LOGARITHM THAT ENSURES THE MAXIMUM RESULT

      Basal implants are very sharp and can thread the hard laminar pits, the most resistant ones, to make them solid support for immediate prosthetic loading. They have been designed with a thin and minimally invasive core with a rounded apex, right where the spiral is born. This first anchoring allows stabilization of the implant apex in cortical support, thus concluding and finalizing the surgery performed with the bicortical technique. Each available size has been designed to adapt perfectly to the existing bone quality, having each basal implant its own pitch, its own aggressiveness, and its own compression dictated by the logarithm with which it was created.
      Shape

      cylindro-conical

      Material

      titanium

      Connection

      external

      Configuration

      anatomical, spiral

      Use

      one-stage

      Surface Properties

      smooth

      Positioning

      cortical

      Implant diameter

      Min.: 3.6 mm (0.14 in)

      Max.: 5 mm (0.2 in)

      Implant length

      Min.: 8 mm (0.31 in)

      Max.: 29 mm (1.14 in)

      Implant angulation

      30 °